Trouble shootings
Some malfunctions of grinder are not practically serious. You can correct it by yourself. To diagnose and find a solution of the trouble,refer to the diagram below. For other malfunctions, get contact the supplier or a qualified professional.
|
MALFUNCTIONS |
POSSIBLE CAUSES |
SOLUTIONS |
|
The appliance starts occasionally to work |
The connected pipelines are leaking |
Check the installation in front of the appliance |
|
The check valve is leaking |
Clean or replace the check valve |
|
|
The motor is running properly, but the water runs slowly away |
The aerator in the lid is blocked |
Clean the aerator |
|
The engine is running properly, but non-stop or runs for a long time |
The height or length of the drain is too large or too many bends are used(power failure) |
Check the installation |
|
The pump is blocked |
Turn off the power, disassemble the pump and unblock |
|
|
The motor is not switched on |
The power supply is not switched |
Switch on power supply(repeat) |
|
The plug is defective |
Repair the plug |
|
|
Trouble with the motor or sensor |
Remove the lid, flush clean. Dry the sensor up(hair dryer) |
|
|
The motor rattles with a noise |
There's strange object in the motor |
Remove the lid, clean it and remove the object |
|
The motor is buzzing and not rotate |
The condensator is broken or has a trouble with the motor |
Get contact with a qualified specialist or the supplier |
|
There's a strange object in the motor |
Remove the lid, clean it and remove the object |
CAUTION
Do not discharge any acids,alkaloids, solvents painting, paintstrippers, food waste, plasticbags, metal such as nails,hairpins, wood building materialskitty litter or anything that couldhalt or damage or corrode theunit. Disregarding the abovemight damage the macerating unitand shall void your warranty.
Please turn off the power before repairing by yourself !!!
If you have any other problems, please contact us.